Run and monitor

Tab 5 is the gateway’s dashboard: whether the service runs, what it is sending, and the state of every machine it reads.

Start the service

The installer starts the service, and it waits until it has a token and a password. Once tabs 1 and 2 are filled in, it begins on its own. If it is stopped, click Start the service on tab 5. Run.

  • The service starts with Windows and runs with nobody logged in.
  • Closing the app stops nothing. Only Stop the service does, and it asks first: no machine data is sent until it starts again, or Windows restarts.
  • Opened by someone who is not an administrator, the app shows only this tab, with an Open as administrator button. Anyone may watch the machines and send diagnostics.

The status line

It saysMeaning
RunningAll good: machine data is read and Nexa answers.
Running, waiting for the machine data serverAn OPC UA server does not answer. With several down it says how many. See Machine data.
Running, Nexa unreachable: bufferingMachines are read, but Nexa cannot be reached. Data waits on the PC and is sent when the connection is back.
Service stoppedNothing is read or sent. Click Start the service.
The Nexa Edge service is not installed. Reinstall Nexa Edge.Run the installer again; your settings are kept.

The figures

FigureWhat it counts
Machine data serversOPC UA servers connected, of those configured.
NexaWhether Nexa answered the last call, or the last error if it did not.
Linked tagsTags linked to machines in Nexa that this gateway reads.
Machines fully readMachines whose every tag has a good value, of all the machines it reads.
SentMinutes and readings Nexa has accepted since the service started.
Waiting to sendBatches buffered on the PC. Rises while Nexa is unreachable, then falls back to zero.
Rejected by NexaReadings Nexa refused as invalid. Should stay at zero; if not, send diagnostics.
Sending rulesEvery linked tag, or how many tags are sent and held back by the rules of tab 4, and whether it is outside the upload window.

Each machine

Below the figures, every machine the gateway reads, problems first, with since when it has been in that state and when its data last changed.

StateMeaning
DisconnectedIts OPC UA server is down, or none of its tags has a good value. Shows within seconds of the server going away.
Partly readSome of its tags have no good value. Check those tags in the OPC UA server.
No data yetJust linked, or the service just started.
FlowingEvery tag is read.

What you see in Nexa

On each linked machine’s Live tab:

  • The gateway’s state: online if it was heard from in the last two minutes, with its last contact.
  • Live values, refreshed every 2 seconds while someone has the tab open, and the last 30 minutes as a chart.
  • Machine alarms from the fault tag, for the last two hours. A major fault also opens an unplanned downtime on the machine, closed when the fault clears.
  • Trend rules: Nexa can warn when a measurement is heading for a limit, and suggest work before it gets there.

The first values

Live values appear within seconds of opening the Live tab. Minute data arrives about five seconds after each minute ends, so the charts and counts fill in from the next minute on.

Without the app

The service is an ordinary Windows service, so IT can also manage it from Services (services.msc) or an elevated prompt:

Get-Service NexaEdge          # is it running?
Restart-Service NexaEdge      # restart it (as administrator)